Surgery · Neurosurgery

Testing the Brain Stem

Brain Stem Death · 2 min

Brain stem death testing checks every reflex the brain stem controls. Reversible causes must be ruled out first.

Before testing, there must be deep coma of known cause, with reversible causes, sedatives and electrolyte, acid-base or temperature problems excluded. The tests check fixed pupils, absent corneal reflexes, no eye movement with ice-cold water in the ears, no motor response to supraorbital pressure, and absent cough and gag. In the apnoea test, there is no breathing as CO₂ rises to at least 6.0 kPa. Testing is done twice by two doctors, one a consultant, neither from the transplant team.